Reactive Power Compensation: Instantly corrects inductive/capacitive reactive power demand, improving power factor to ≥0.99 and reducing energy losses.
Harmonic Mitigation: Suppresses harmonic distortions to THDi < 5%, protecting equipment from damage and ensuring compliance with global standards (IEEE 519, IEC 61000).
Three-Phase Unbalance Control: Balances load currents, enhancing system stability and extending equipment lifespan.
Rapid Response: <10ms reaction time to dynamic load changes, ensuring real-time compensation.
Flexible Configuration: Supports single-phase, three-phase three-wire, and three-phase four-wire systems with modular designs for easy scalability (up to 8 parallel modules).
Wide Operating Range:
Voltage: 220V, 400V, 500V, 690V (±20% tolerance)
Frequency: 50Hz (±5%)
Temperature: -20°C to +50°C, with humidity <90% (non-condensing).
Built to withstand harsh environments with IP20 protection and forced air cooling.
Low noise design (<60dB) and compact sizes for wall-mounted, rack-mounted, or cabinet installations (customizable for specific needs).
Phase Angle Detection: Monitors load current phase vs. voltage to identify lagging/leading reactive power.
Active Compensation: Generates opposite reactive current (leading for inductive loads, lagging for capacitive loads) to align current and voltage phases, achieving near-unity power factor.
Harmonic Filtering: Targets nonlinear load distortions, ensuring clean power supply.
Key Parameter | Industry Standards | Advantages of ARK SVG |
response time | ≤20ms | <10ms (the fastest in the industry) |
Compensation precision | ±5% | ±1% |
efficiency | 95% | >97% |
overload capacity | 120%/1min | 150%/10s |
IP Level | IP20 | IP20 with optional customization |
Manufacturing: Motors, drives, and welding equipment causing harmonic distortions.
Renewables: Solar/wind inverters leading to reactive power fluctuations.
Commercial Grids: Data centers, hospitals, and offices requiring stable, efficient power.
Utilities: Transmission/distribution networks optimizing capacity and reducing losses.
TYPE | Series 220V | Series 400V | Series 500V | Series 690V |
Max neutral w ire current | 5KVar | 10KVar15KVar/ 35KVar/50KVar/ 75KVar/100KVar | 90KVar | 120KVar |
Nominal voltage | AC220V(-20%~+20%) | AC380V(-20%~+20%) | AC500V(-20%~+20%) | AC690V(-20%~+20%) |
Rated frequency | 50Hz±5% | |||
Network | Single phase | Three-phase three-wire/three-phase four-wire | ||
Response time | <10ms | |||
Reactive power compensation rate | >95% | |||
Machine efficiency | >97% | |||
Switching frequency | 32kHz | 16kHz | 12.8kHz | 12.8kHz |
Feature selection | Deal with harmonics/Deal with harmonics and reactive power | Deal with harmonics/Deal with harmonics and reactive power/ Deal with harmonics and three-phase unbalance /Three options | ||
Numbers in parallel | No limitation. A single centralized monitoring module can be equipped with up to 8 power modules | |||
Communication methods | Two-channel RS485 communication interface (support GPRS/WIFIwireless communication) | |||
Altitude w ithout derating | <2000m | |||
Temperature | -20~+50°C | |||
Humidity | <90% RH | |||
Pollution level | Below level Ⅲ | |||
Protection function | Overload protection, hardware over-current protection, over-voltage protection, power grid voltage imbalance protection, power | |||
Noise | <50dB | <60dB | <65dB | |
Installation | Rack/wall hanging | Rack | ||
Into the way of line | Back entry (rack type), top entry (wall-mounted) | Top entry | ||
Protection grade | IP20 |